Citation: | Yu Li, Yuanzhan Yang, Xuefei Lü, Yulin Deng. Aptamer-Based Fluorescent Assay for Sensitive Detection of Cardiac Troponin I[J].JOURNAL OF BEIJING INSTITUTE OF TECHNOLOGY, 2020, 29(1): 45-51.doi:10.15918/j.jbit1004-0579.18131 |
[1] |
Fathil M F M, Arshad M K M, Gopinath S C B, et al. Diagnostics onacutemyocardialinfarction:cardiactroponinbiomarkers[J].Biosens Bioelectron,2015,70:209-220.
|
[2] |
Rezaei Z, Ranjbar B. Ultra-sensitive rapid goldnanoparticle-quantum dot plexcitonicself-assembled aptamer-based nanobiosensorfor the detection of human cardiac troponin I[J]. Eng Life Sci,2017, 17:165-174.
|
[3] |
Dorraj G S, Rassaee M J, Latifi A M, et al. Selection of DNA aptamers against Human Cardiac Troponin I forcolorimetric sensor based dot blot application[J]. J Biotechnol,2015,208:80-86.
|
[4] |
Jo H, Gu H, Jeon W, et al. Electrochemical aptasensor of cardiac troponin I for the early diagnosis of acute myocardial infarction[J].Anal Chem, 2015,87:9869-9875.
|
[5] |
Kim W J, Cho H Y, Kim B K, et al. Highly sensitive detection of cardiac troponin I in human serum using gold nanoparticle-based enhanced sandwich immunoassay[J].Sensor Actuat B-Chem, 2015,221:537-543.
|
[6] |
Lee W S, Sunkara V, Han J R, et al. Electrospun TiO2 nanofiber integrated lab-on-a-disc for ultrasensitive protein detection from whole blood[J]. Lab Chip, 2015, 15:478-485.
|
[7] |
Zhou F, Lu M, Wang W, et al. Electrochemical immunosensor for simultaneous detection of dual cardiac markers based on a poly(dimethylsiloxane)-gold nanoparticles composite microfluidic chip:a proof of principle[J]. Clin Chem, 2010, 56:1701-1707.
|
[8] |
Akter F, Mie M, Kobatake E. DNA-based immunoassays for sensitive detection of protein[J].Sensor Actuat B-Chem, 2014,202:1248-1256.
|
[9] |
Deng R J, Zhang K X, Li J H. Isothermal amplification for microRNA detection:from the test tube to the cell[J]. Acc Chem Res, 2017, 50:1059-1068.
|
[10] |
Schweitzer B, Wiltshire S, Lambert J, et al. Immunoassays with rolling circle DNA amplification:a versatile platform for ultrasensitive antigen detection[J].P Natl Acad Sci USA, 2000,97:10113-10119.
|
[11] |
Chen C H, Luo M, Ye T, et al. Sensitive colorimetric detection of protein by gold nanoparticles and rolling circle amplification[J].Analyst, 2015,140:4515-4520.
|
[12] |
Chen H, Wu S Y, Dong F, et al. A novel chemiluminescence immunoassay for highly sensitive and specific detection of protein using rolling circle amplification and the multiplex binding system[J].Sensor Actuat B-Chem, 2015,221:328-333.
|
[13] |
Cheng W, Yan F, Ding L, et al. Cascade signal amplification strategy for subattomolarprotein detection by rolling circle amplification and quantum dots tagging[J]. Anal Chem, 2010, 82:3337-3342.
|
[14] |
Wu L D, Ma C, Zheng X X, et al. Paper-based electrochemiluminescence origami device for protein detection using assembled cascade DNA-carbon dots nanotags based on rolling circle amplification[J].Biosens Bioelectron,2015,68:413-420.
|
[15] |
Wang P, Jin B, Xing Y S, et al. Rolling circle amplification immunoassay combined with gold nanoparticle aggregates for colorimetric detection of protein[J].J Nanosci Nanotechno, 2014, 14:5662-5668.
|
[16] |
Zhou L, Ou L J, Chu X, et al. Aptamer-based rolling circle amplification:a platform for electrochemical detection of protein[J].Anal Chem, 2007,79:7492-7500.
|
[17] |
Bi S, Li L, Zhang S S. Triggered polycatenated DNA scaffolds for DNA sensors and aptasensors by a combination of rolling circle amplification and DNAzyme amplification[J]. Anal Chem,2010,82:9447-9454.
|
[18] |
Lee J, Icoz K, Roberts A, et al. Diffractometric detection of proteins using microbead-basedrolling circle amplification[J].Anal Chem,2010,82:197-202.
|
[19] |
Tang L H, Liu Y, Ali M M, et al. Colorimetric and ultrasensitive bioassay based on a dual-amplification system using aptamer and DNAzyme[J].Anal Chem,2012,84:4711-4717.
|
[20] |
Yao L Y, Yu X Q, Zhao Y J, et al. An aptamer-based chemiluminescence method for ultrasensitive detection of platelet-derived growth factor by cascade amplification combining rolling circle amplification with hydroxylamine-enlarged gold nanoparticles[J].Anal Methods, 2015,7:8786-8792.
|
[21] |
Jo H, Her J, Lee H, et al. Highly sensitive amperometric detection of cardiac troponin I using sandwich aptamers and screen-printed carbon electrodes[J].Talanta,2017, 165:442-448.
|