Ping Lang, Lei Han. Simplified Modeling and Mathematical Analysis in Cardiac Electric Field Propagation for Human and Animals[J]. JOURNAL OF BEIJING INSTITUTE OF TECHNOLOGY, 2020, 29(2): 167-176. doi: 10.15918/j.jbit1004-0579.19104
Citation: Ping Lang, Lei Han. Simplified Modeling and Mathematical Analysis in Cardiac Electric Field Propagation for Human and Animals[J].JOURNAL OF BEIJING INSTITUTE OF TECHNOLOGY, 2020, 29(2): 167-176.doi:10.15918/j.jbit1004-0579.19104

Simplified Modeling and Mathematical Analysis in Cardiac Electric Field Propagation for Human and Animals

doi:10.15918/j.jbit1004-0579.19104
  • Received Date:2019-11-25
  • The different characteristics of cardiac electric field (CEF) radiation in humans and other animals are presented in this paper. Physical modeling and mathematical analysis are developed to comprehensively unveil the properties of CEF, based on typical heartbeat waveforms. Our numerical simulation results demonstrate that the frequency bandwidths and the cycle durations of CEF are different for healthy humans versus humans on the verge of death and for humans versus other animals. The results indicate that the present study may extensively contribute towards recognizing human beings or other animal targets quickly and accurately with CEF in dangerous situations or in other applications.
  • loading
  • [1]
    Dogaru T, Nguyen L, Le C. Computer models of the human body signature for sensing through the wall radar applications[M]. Adelphi, M D: Army Research Laboratory, 2007.
    [2]
    Nishi M, Takahashi S, Yoshida T, et al. Indoor human detection systems using VHF-FM and UHF-TV broadcasting waves[C]// Personal, Indoor and Mobile Radio Communications, 2006: 1-5.
    [3]
    Wu Chiwei, Huang Ziyu. Using the phase change of a reflected microwave to detect a human subject behind a barrier [J]. IEEE Trans Biomed Eng, 2008, 55(1): 267-272
    [4]
    Kurita K. Detection for human respiration and human heartbeat under non-contact conditions[C]// Robotics and Biomimetics, 2011: 1831-1836.
    [5]
    Kurita K. Non-contact detection of human heartbeat based on measurement of current generated by electrostatic induction[C]// Society of Instrument and Control Engineers of Japan, 2012: 988-992.
    [6]
    Kurita K, Nonaka T, Kumon H, et al. Measurement of human heartbeat using a novel sensing technique based on measurement of current generated by electrostatic induction[C]// Society of Instrument and Control Engineers of Japan, 2010: 3340-3343.
    [7]
    Lang Ping, Han Lei. The analysis and comparison of cardiac electric field for humans and other animals[C]// International Conference on Mechatronics and Automation Engineering, 2016. (in Chinese)
    [8]
    Han Lei, Lang Ping, Li Yan. Analysis of human cardiac electric field applied in passive non-contact detection [J]. Transactions of Beijing Institute of Technology, 2017(37): 168-172. (in Chinese)
    [9]
    Zhu Daimo. Head and chest leads and electrocardiographic dipole theory [J]. Chinese Journal of Medical Physics, 1991(4). (in Chinese)
    [10]
    Zhu Daimo. A new method of calculating the potential of eccentric dipole on weak surface to dielectric sphere [J]. Chinese Journal of Medical Physics, 1991(3). (in Chinese)
    [11]
    Shahidi A V, Guardo R, Savard, P. Impedance tomography: Computational analysis based on finite element models of a cylinder and a human thorax [J]. Ann Biomed Eng, 1995, 23: 61-69
    [12]
    Shahidi A V, Savard P, Nadeau R. Forward and inverse problems of electrocardiography: modeling and recovery of epicardial potentials in humans [J]. IEEE Transactions on Biomedical Engineering, 1994, 41(3): 249-256
    [13]
    Rudy Y, Plonsey R. A comparison of volume conductor and source geometry effects on body surface and epicardial potentials [J]. Circulation Research, 1980, 46(2): 283-291
    [14]
    Miyanaga T, Urabe W, Nakano Y. Simplified human body model for evaluating thermal radiant environment in a radiant cooled space [J]. Building & Environment, 2001, 36(7): 801-808
    [15]
    Lu Yanhui. Infrared method for measuring the thickness of subcutaneous fat in human body[D]. Tianjing: Tianjin University, 2004. (in Chinese)
    [16]
    Zhang Kai, Hao Qun, Song Yong, et al. Modeling and characterization of the implant intra-body communication based on capacitive coupling using a transfer function method [J]. Sensors, 2014, 14(1): 1740-1756
    [17]
    Zhao Yue. Heart impedance detection and signal analysis methods[D]. Shenyang: Shenyang University of Industrial, 2015. (in Chinese)
    [18]
    Gabriel S, Lau R W, Gabriel C, et al. The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues [J]. Physics in Medicine and Biology, 1996, 41(11): 2271-2293
    [19]
    Li Cunyu. Five steps and application of electrocardiology analysis [J]. Journal of Clinical Electrocardiology, 2012, 21(3): 223-226
    [20]
    Yu Zhiming. The normal electrocardiogram of dog [J]. The Magazine of Zoology, 1980(1): 24-28
    [21]
    Zhao Chunfeng, Liyuhong, Lihui. The electrocardiology analysis of normal guinea pig in the awake state [J]. The Journal of Liaoning Chinese Medicine University, 2010, 12(8): 55-56
    [22]
    Zhao Jianing, Gu Weiwang, Wu qinghong, et al. The ECG determination of SPF new zealand rabbit [J]. Progress in Veterinary Medicine, 2005(9): 116-117
    [23]
    Cao Xiwu, Deng Qinkai. The frequency analysis of ECG wave [J]. Chinese Journal of Medical Physics, 2001(1): 46-48. (in Chinese)
  • 加载中

Catalog

    通讯作者:陈斌, bchen63@163.com
    • 1.

      沈阳化工大学材料科学与工程学院 沈阳 110142

    1. 本站搜索
    2. 百度学术搜索
    3. 万方数据库搜索
    4. CNKI搜索

    Article Metrics

    Article views (525) PDF downloads(523) Cited by()
    Proportional views
    Related

    /

      Return
      Return
        Baidu
        map