  • Insulating parts are easily subjected to pollution which may cause damage to the electric system. A typical disc insulator is chosen as the target to test its flashover voltage by using an artificial pollution system. This test system aims at obtaining characteristic parameters of damage for chosen conducting sols to the selected insulator. Experimental results show that thickness and electric conductivity of pollutant layer over insulators are the main parameters in damage evaluation. The flashover voltage decreases with increase of thickness and/or conductivity. These results provide a better basis on further revealing the damaging nature of conducting sol materials.
  • loading
  • [1]
    Su Zhiyi. To intensify basic external insulation level of power system-fundamental way for prevention of large-scale pollution flashover . Electric Power, 2003, 36(12): 57-61. (in Chinese)
    [2]
    Farzaneh M, Fofana I, Tavakoli C. Dynamic modeling of dc arc discharge on ice surfaces[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2003, 10(3): 463-574.
    [3]
    Wieck H, Gutman I, Ohnstad T. Investigation of flashover performance of snow-covered breakers[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2007, 14(6): 1339-1346.
    [4]
    Khan A A, Masood A, Husain E. A study of flashover voltage of artificially polluted porcelain disc insulator under natural fog conditions //2008 International Conference on Condition Monitoring and Diagnosis. Beijing: IEEE, 2008: 369-371.
    [5]
    Lan L, Gorur R S. Computation of ac wet flashover voltage of ceramic and composite insulators[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2008, 15(5): 1346-1352.
    [6]
    Williamson Charles, Saha Tapan Kumar. Wet-test performance of insulating fibreglass sticks used for live working[J]. Journal of Electrical and Electronics Engineering, 2002, 21(3):189-198.
    [7]
    Guan Z C, Wang L M, Yang B. Study on the polluted regularity of insulators quantitatively described by partial surface conductivity //Proceedings of the International Symposium on Electrical Insulating Materials. Tokyo: ISEIM, 2001: 293-296.
    [8]
    Dhahbi-Megriche N, Beroual A. Predictive dynamic model of the leakage current and flashover voltage of discontinuously polluted insulators under ac voltage[J]. Journal of Physics D, 2007, 40(24):7782-7786.
    [9]
    Jiang Xingliang, Yuan Jihe, Zhang Zhijin. Study on pollution flashover performance of short samples of composite insulators intended for ±800?kV UHV DC[J]. IEEE Transactions on Dielectrics and Electrical Insulation, 2007, 14(5): 1192-1200. (Edited by